Termostable ferrites for weak magnetic fields



the Main fields of application

Cores for the RF paths, transformers HF frequency range, cores for filters RF-interference, antenna couplers, dividers and faucets HF frequency range.

Cores from ferrite grades DOWN it is recommended to use in weak magnetic fields at an ambient temperature of 60 º C to +125 º C, and in the frequency range: 20VN - up to 100 Mhz, 30VN - up to 120 Mhz, 50VN-up to 50MHz.

Cores of ferrites brands HV is not recommended for use in magnetic fields greater than the so-called threshold of the field, because in excess of the specified field values ​​is a significant decrease of good quality. The value of the threshold field are: to 20VN, 30VN 50VN and -150 A / mμn it practically does not change.

inductors and podstroechniki with a high q-factor in the operating frequency range and with small values ​​of the relative temperature coefficient μn to telephone and radio communications equipment (including for railway the means of communication).

Cores from ferrite grades nm1, NM3 it is recommended to use at ambient temperature from 60 º C to +150 º C, and in the frequency range: 1500NM1, 1500NM3 - up to 600 Khz, 2000NM1 - up to 450 Khz.



Dependence of loss on frequency
Dependence of the relative tangent of the angle of the magnetic losses from frequency
thermostable ferrites



the Dependence of the initial magnetic permeability of temperature
the Dependence of the initial magnetic permeability
from temperature for ferrites brands 20ВН, 30ВН, 50ВН



Зависимоть tangent losses from the strength of the magnetic field Зависимоть tangent losses from the strength of the magnetic field
the Dependence of the tangent of the angle of the magnetic losses
from the strength of the magnetic field for thermostable ferrites
(---) - for the constant magnetic field



the Relative change of the initial magnetic permeability depending on the temperature
the Relative change of the initial magnetic permeability depending on the temperature the Relative change of the initial magnetic permeability depending on the temperature
the Relative change of the initial magnetic permeability depending on the temperature the Relative change of the initial magnetic permeability depending on the temperature
the Relative change of the initial magnetic permeability
from temperature for ferrites brands 20ВН, 30ВН, 50ВН, 1500НМ3, 2000НМ1



the Curie Point
the Value of the Curie point for ferrites brands 1500НМ3, 2000НМ1